• 11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation
  • 11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation
  • 11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation
  • 11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation
  • 11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation
  • 11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation

11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation

Application: Power, Electronic, Instrument, Lighting
Phase: Three
Core: Core-type Transformer
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation pictures & photos
11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation
US $1,000-50,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
IBK-KBSGZY 10KV
Cooling Method
Dry-type Transformer
Winding Type
Separated Winding Transformer
Certification
ISO9001, CCC
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
EE
Brand
Abilkeen
Product Name
Distribution Transformer
Primary Voltage
6.3kv, 10kv, 11kv, 15kv
Secondary Voltage
0.4kv/0.415kv/0.433kv
Rated Capacity
Rated Capacity
Standard
IEC60076, GB1094-1996; Jb/T10088-2004; GB/T6451-20
Vector Group
Vector Group
Transport Package
Wooden Case
Specification
6kv 10kv 11kv 25 Kv 100kVA, 400kVA 200kVA
Trademark
ABILKEEN
Origin
China
HS Code
8504339000
Production Capacity
999999/Month

Packaging & Delivery

Package Size
200.00cm * 60.00cm * 200.00cm
Package Gross Weight
100.000kg

Product Description

Product Description

11kV Three Phase KBSGZY Series Dry Type Mining Explosion Isolation Movable Transformer Substation

11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation

Detailed Photos

1. Standard: GB1094-1996; JB/T10088-2004; GB/T10228-2008; EQV IEC726
2. Voltage Grade: 33kV,35KV 3. Voltage Regulation Mode: No-load tap changing or On-load tap changing 4. Tapping Range: ±5%, ±2×2.5%, ±4×2.5% or others 5. Frequency: 50Hz; 60Hz 6. Phase: three phase
7. Connection Sign: Dyn5,Yyn0, Dyn11 or others
8. Short Circuit Impedance: Standard impedance (For details see technical data sheet)
9. Max. Temperature: 120ºC
10. Cooling Method: AN or AF
11. Insulation Class: Grade F/H
 

Features: Power grid electric transformer

High voltage coils are wrapped with Polyester enameled wires, filled with glass fiber, and then resin under vacuum condition. It becomes solid under high temperature. It equipped with high mechanical intensity, low discharge partly; Low voltage coils are wrapped with a whole piece of copper foil, with strong anti-shortcut capacity. The core is made of silicon steel.
By reasonable choosing magnetic density, decrease the empty loading loss effectively.Fire protection, anti-explosion, and no pollution.
Coil is free from humidity, low noise and well characteristic of heating dispersion
Low loss, energy saving, free from maintenance, small size, light, and easy for installation.
Technical Data of 11kV Three Phase KBSGZY Series Dry Type Mining Explosion Isolation Movable Transformer Substation
      Loss (kW)     Weight (kg) (mm) Gauge(mm)
Rated Capacity Voltage Group(kV) Connection Method             (145) No-load current Impedance (L) (W) (H)  
(kVA) HV LV No-load Load % %   Dimension
50 10±5% 11±5% 0.693/0.4 1.2/0.693  1.2        3.45   Yy0        (d11) 390 680 2.5 4 2400 3200 950 1295 600
100 560 1050 2.5 4 2800 3580 950 1430
200 950 1800 2 4 3200 3990 950 1525 600          900
250 1100 2100 2 4 3500 4020 950 1540
315 1300 2500 1.8 4 3800 4050 980 1555
400 1500 3000 1.8 4 4000 4200 1050 1610
500 1750 3500 1.5 4 4300 4200 1050 1610
630 2000 4100 1.5 4 5400 4370 1080 1450
800 Yy0        (d11)  Dyn11 2300 5100 1.2 4 5700 4370 1080 1600
1000 2600 6100 1.2 4.5 6900 4400 1110 1675
1250 3100 7400 1 4.5 7300 4480 1125 1740
1600 3800 8500 1 5 9300 4640 1245 1830
2000 4500 9700 0.7 5 11900 4665 1250 1900
2500 5200 10800 0.7 5.5 14930 4870 1390 1900
3150 6100 12800 0.7 5.5 19350 4880 1390 1900
4000 7000 15000 0.7 6 21910 5210 1450 1900
(Note): (Tapping range of high voltage) ±5%; ±2×2.5%, Frequency: 50Hz. The above data provides a reference only, movable transformer sustation the basis switch of the shape size  of transformer substation different but different.

11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation

Certifications

11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation

Packaging & Shipping

11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation

Company Profile

11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation

FAQ

Q1. What is your terms of packing? 11KV oil transformer distribution transformer power transformer manufacturer
A: Generally, we pack our goods in neutral white boxes and brown cartons. If you have legally registered patent, we can pack the goods in your branded boxes after getting your authorization letters.

Q2. What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.

Q3. What is your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.

Q4. How about your delivery time? waterproof push button switch
A: Generally, it will take 3 to 10 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.

Q5. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.

Q6. What is your sample policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.

Q7. Do you test all your goods before delivery?
A: Yes, we have 100% test before delivery

Q8: How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation pictures & photos
11kv Three Phase Kbsgzy Series Dry Type Mining Explosion Isolation Movable Transformer Substation
US $1,000-50,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
102
Year of Establishment
2014-09-05